On Fri, 25 Sep 1998 20:28:51 -0700 zeitler@ibm.net writes:
>
>Steve,
>Be careful. I believe Doug used an old NRC R-175A plate choke. Check 
>for
>resonances before applying the juice!! His original intent with this 
>article
>and hence the selection of this specific choke was to convert the 
>SB200 for
>use as a LOW BAND amp only, ie 160/80/40 meters.


The B&W 802 choke will work also if you can find one. 160-10M plus WARC.
If that is not available call Ameritron and get one of their 811A or
AL-80 amp chokes.

73  Carl  KM1H