>Dentron MLA-2500 to 6 meters
>
> Has anyone tried changing the 10m tap on this amp to put it on 6m.
In a VHF amplifier design, it is even more important to locate C-tune
close to the anode(s). In the MLA-2500, C-tune is located at the front
of the chassis while the amplifier tubes are located at the rear of the
chassis. It is my opinion that a serious relocation and electrical mod
job is in order.
>Thought that since it has no tuned input there might be an easy
>conversion to 6 meters. Any thoughts on this..
>--
Adding tuned input is Definitely easier with single band operation. //
The current C-tune has too much min-C for a 6m design, however, it might
work for C-load. I would be looking for an approx. 30pF unit for C-tune.
I have a few available at the price of shipping.
- later, Robert
Rich...
R. L. Measures, 805-386-3734, AG6K, www.vcnet.com/measures
--
FAQ on WWW: http://www.contesting.com/ampfaq.html
Submissions: amps@contesting.com
Administrative requests: amps-REQUEST@contesting.com
Problems: owner-amps@contesting.com
Search: http://www.contesting.com/km9p/search.htm
|