Date: Tue, 25 Feb 1997 09:30:16 -0500 (EST)
>       by dayton.akorn.net (8.8.5/8.8.5) with ESMTP id JAA02701
>       for <amps@contesting.com>; Tue, 25 Feb 1997 09:19:11 -0500 (EST)
>From: km1h@juno.com
>Received: (from km1h@juno.com) by x6.boston.juno.com (queuemail)
>       id JzS28141; Tue, 25 Feb 1997 09:18:32 EST
>To: amps@contesting.com
>Cc: 
>Subject: Re: [AMPS] 3-500Z storage
>Message-ID: <19970225.092000.9887.26.km1h@juno.com>
>References: <3.0.32.19970224172350.00a213e8@pop.uky.edu>
>X-Mailer: Juno 1.15
>X-Juno-Line-Breaks: 3-4,14-15,20-21,26-27,30-32
To: <amps@contesting.com>
>Date: Tue, 25 Feb 1997 09:18:32 EST
>
>Bill, the only cure I have heard that works for gas in a tungsten
>filament tube is to run the tube with a bit of color (with full air) and
>periodically checking. I have no idea how effective this is with varying
>amounts of gas. 
>
>The storage issue came up around 1992-93 or so when a unusual number of
>horizontally stored NIB 3-500Z' s were reported shorted upon turn-on.
>Many guys called EIMAC for warranty replacement and were told that those
>tubes should only be stored vertically. This was reported on packet and
>in various contest newsletters then.  Other comments notwithstanding, I
>would tend to lean to the manufacturers suggestions and play it safe. It
>was also around this time that EIMAC became very strict with the 1 year
>from date code warranty policy. I can't say for sure but there were a lot
>of rumors flying around about some cost cutting manufacturing changes,
>quality control and other plant problems.  
>
>Bringing the PS up with a Variac is a good idea. If one is not available
>you can use a 120V line with the amp wired for 240V as a means of
>reducing the input current shock. The old light bulb in series with the
>AC line trick works well also.  After only a 3 year sitting period, the
>odds of cap problems are slim. 
>
>There is one procedure that should be followed with old or new PS caps.
>That is to measure the voltage drop across each one. There should be
>about a 10% maximum variation and with none exceeding the cap ratings. I
>have observed even new out of the box computer grade caps, from the same
>date code run, that are way out of tolerance....by as much as 50-60%.
>
>Heat is a real killer in that Drake PS and a muffin fan would be a big
>plus. Almost forgot.....At least check those 100K carbon equalizing
>resistors for 5% tolerance. Better still replace with 3W metal oxide. 
>
>GL.....Carl    KM1H 
>
>
Sender: owner-amps@contesting.com
Precedence: bulk


--
FAQ on WWW:               http://www.contesting.com/ampfaq.html
Submissions:              amps@contesting.com
Administrative requests:  amps-REQUEST@contesting.com
Problems:                 owner-amps@contesting.com
Sponsored by:             Akorn Access, Inc. & N4VJ / K4AAA


<Prev in Thread] Current Thread [Next in Thread>