To: | amps@contesting.com |
---|---|
Subject: | [Amps] Henry 2K desktop |
From: | Don via Amps <amps@contesting.com> |
Reply-to: | taurusshoguy@yahoo.com |
Date: | Sat, 29 Jun 2019 20:35:30 +0000 (UTC) |
List-post: | <mailto:amps@contesting.com> |
Henry wires their filaments in series, so if you remove on tube it won't work. I would remove the suspect 3-500 after making sure all HV is discharged, and see if it's filament has continuity. If that tube has an internal short, that would account for your SWR issue also. Don N8ECH _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | [Amps] Re Henry 2K desktop amp, Joe Cucuzza |
---|---|
Next by Date: | [Amps] Henry filament problem solved!, Ted Rachwal |
Previous by Thread: | [Amps] Re Henry 2K desktop amp, Joe Cucuzza |
Next by Thread: | [Amps] Henry filament problem solved!, Ted Rachwal |
Indexes: | [Date] [Thread] [Top] [All Lists] |