> I just picked up a perfect SB-221 Heathkit Amp.  I like it, however, I don't
> like the fact that when you switch it on, the B+ comes on with the filaments.
>  I would like to be able to enable the B+ and antenna changeover relay
> together, so the filaments could remain lit but the amp brought on line only
> when needed.   Any thoughts?
>
Invest your time and money in a step-start and the other glitch mods.
I can't think of a single advantage of separate HV control.

(((73)))
Phil, K5PC




--